Get complete information related to latest Transformer Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Repair Tenders.
Tender For for the safety of kavand passengers, repair of 11 gw 33 gw pure power line and temporary barricading of transformers, repair of green wires and bent poles and plastic insulation on iron poles for the safety of kavand passengers in the area of power distribution sub-division, nagal, under the power distribution division, devbad. the work of installing tar and reflected tape
Tender For under the power distribution division of devbud, in the area of power distribution sub-division of devbud i and talheri buzurg, for the safety of kavand passengers, repair of 11 gw 33 gw pure power line and temporary barricading of transformers, repair of green wires and bent poles, and laying of plastic insulation on iron poles. work of installing concrete and reflected tape
Tender For for the safety of kavand commuters, repair of 11 gw 33 gw electric power line and temporary barricading of transformers, repair of green wires and bent poles, and plastic insulation on iron poles for the safety of kawand passengers in the area of power distribution sub-division deobad ii (rural) under the power distribution division of devbud. work of installing ¼ glass cover sheet and reflected tape.
Tender For corrigendum : maintenance of damaged tin shed glass panes of windows maintenance of toilet and other related civil works at electricity transformerrepairing workshop sachendi kanpur nagar
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For tender for procurement of miscellaneous of material for repairing/maintenance of distribution transformers at in-house transformerrepairing centre under bodeli division. - super enameled aluminium 'h' class wire of 22 guage as per is 13730(part-0/sec-3) : 2012, super enameled aluminium 'h' class wire of 22.5guage as per is 13730(part-0/sec-3) : 2012
Tender For tender for procurement of miscellaneous of material for repairing/maintenance of distribution transformers at in-house transformerrepairing centre under bodeli division - super enameled aluminium 'h' class wire of 20 guage as per is 13730(part-0/sec-3) : 2012, super enameled aluminium 'h' class wire of 21 guage as per is 13730(part-0/sec-3) : 2012
Tender For tender for procurement of miscellaneous of material for repairing/maintenance of distribution transformers at in-house transformerrepairing centre under bodeli division. - 2mill dpc paper roll of 10 to 20mm approved manufacturer, ,insulation press pram paper in various size 4 mil approved manufacturers ,insulation press pram paper in various size 20 mil approved manufacturers ,insulation press pram paper in various size 10 mil approved manufacturers ,insulation crepe tube size 8x12 mm approved manufacturers nos 1000 38 08000 ,insulation craft paper of size 34" & 1" approved manufacturers ,insulation sleeve (fiber glass) approved manufacturers
Tender For tender for procurement of miscellaneous of material for repairing/maintenance of distribution transformers at in-house transformerrepairing centre under bodeli division. including gst. - lt bushing 1 kv class as per is 3347 from approved manufacturers ,ht metal part for transfomer 134 x 12 mm size: 12 mm dia. 134 mm length, 1.75 mm pitch, 17.5 kv 250 amp) from approved manufacturers ,lt metal part for transfomer 205 x 12 mm ,size: 12 mm dia. 205 mm length, 1.75 mm pitch from approved manufacturers ,rubber nitrile goti 12 mm ht from approved manufacturers ,rubber nitrile goti 12 mm lt from approved manufacturers ,lt cork sheet gasket 32x12x5 mm from approved manufacturers ,lt cork sheet gasket 45x20x5 mm from approved manufacturers ,lt cork sheet gasket 110x70x5 mm from approved manufacturers ,cotton tape approved manufacturers ,m.s. nut bolt 10mm for transformerrepairing